Programmable Setback Thermostats

 Braeburn Thermostats

 
Thermostats Thermostats Zoning Systems Zoning Systems Humidification Humidification Humidification Accessories Humidification Accessories NEW 5300
 
Model Description Staging Power Warranty
500 Mechanical Thermostat 1 Heat / 1 Cool 24 VAC 1 Year
505 Mechanical Heat Only 24 VAC 1 Year
507 Mechanical Cool Only 24 VAC 1 Year
1000 Non-Programmable 1 Heat / 1 Cool Battery, Hardwire 5 Year
1000NC Economy Non-Programmable 1 Heat / 1 Cool Battery, Hardwire 2 Year
1000TL Economy Non-Programmable 1 Heat / 1 Cool Battery, Hardwire 2 Year
1005 Non-Programmable Heat or Cool Only Battery 5 Year
1005NC Economy Non-Programmable Heat or Cool Only Battery 2 Year
1200 Non-Programmable 2 Heat / 1 Cool Battery, Hardwire 5 Year
1200NC Economy Non-Programmable 2 Heat / 1 Cool Battery, Hardwire 2 Year
2000 5-2 Day Programmable 1 Heat / 1 Cool Battery, Hardwire 5 Year
2000NC Economy 5-2 Day Programmable 1 Heat / 1 Cool Battery, Hardwire 2 Year
2200 5-2 Day Programmable 2 Heat / 1 Cool Battery, Hardwire 5 Year
3000 Non-Programmable 1 Heat / 1 Cool Battery, Hardwire 5 Year
3200 Non-Programmable 2 Heat / 2 Cool Battery, Hardwire 5 Year
3300 Non-Programmable 3 Heat / 2 Cool Battery, Hardwire 5 Year
5000 7 Day, 5-2 Day Programmable 1 Heat / 1 Cool Battery, Hardwire 5 Year
5200 7 Day, 5-2 Day or Non-Programmable 2 Heat / 2 Cool Battery, Hardwire 5 Year
5300 7 Day, 5-2 Day or Non-Programmable 3 Heat / 2 Cool Battery, Hardwire 5 Year
5400 7 Day, 5-2 Day or Non-Programmable 3 Heat / 2 Cool Battery, Hardwire 5 Year

 

 

Click here for Web site link for t-stat demo

      

9701i
1 Heat / 1 Cool

  • Compatible with all single stage 24 VAC Heating and Cooling, including single stage heat pump systems
  • 7-Day, 5-2, 5-1-1 or 24 hour programming
  • 2, 4 or 6 events per day
  • Worry-Free Memory Retention
  • ENERGY STAR rated for energy savings
  • Residual Cooling
  • Indoor/Outdoor Sensor Capable

9720i
2 Heat / 2 Cool

  • Compatible with all standard 24 VAC heat pump systems, up to two stage heat and two stage cool
  • 7-Day, 5-2, 5-1-1 or 24 hour Programming
  • 2, 4 or 6 events per day
  • Worry-Free Memory Retention-
  • Adjustable 1st and 2nd Stage Differential
  • ENERGY STAR rated for energy savings
  • Indoor/Outdoor Sensor Capable

9715i
2 Heat / 2 Cool

  • Compatible with all standard 24 VAC heating and cooling, including single stage heat pump systems
  • 7-Day, 5-2, 5-1-1 or 24 hour Programming
  • 2, 4 or 6 events per day
  • Worry-Free Memory Retention
  • ENERGY STAR rated for energy savings
  • Indoor/Outdoor
  • Adjustable 1st and 2nd Stage Differential

Save energy.

Thermostat Guards- Honeywell's Versaguard is available for virtually any wall mounted thermostat.
Honeywell's complete selection of universal thermostat guards provides maximum protection from tampering and damage. Available in three sizes, and with the choice of clear plastic, opaque plastic or scratch-resistant metal covers.

Humidifiers- The recommended indoor relative humidity is 35% to 45%.

Heated air dries out and shrinks wood framing around doors and window frames. Gaps occur, permitting cold outside air infiltration. Heat loss and higher heating costs are often the result. Heated, parched air causes separation of wood in floors, trim and furniture...wall and ceiling cracks...plant damage and annoying static shocks are also a by-product of dry air.

Proper humidity reduces heating costs by stopping wood shrinkage, which reduces cold air infiltration around door and window frames. In turn, you will feel warm at lower temperatures. You can actually lower your thermostat and still be comfortable. In cases where excessive dry air has been the cause of physical aggravations, doctors have prescribed whole-house humidification. Proper humidity also protects your furnishings, wood floors and plants.

 

Electronic Air Cleaners- High efficiency air filtering removes up to 95% of the irritating airborne particles, like pollen, bacteria, viruses and dust mites. Cleaner air circulating through your equipment keeps it cleaner, therefore reducing operating costs by 10 to 15% over the life of the equipment.

picture of  Honeywell electronic air cleaner. 2.6k The F50 series air cleaners are duct-mounted models of 2-cell design. Mounts in return air duct and can be installed for air flow in either direction through the cells. Completely assembled and pre-wired, equipped with integral sail switch to simplify control wiring and only allow the unit to run while the system fan is running. Includes cabinet, cells, power supply, junction box, service door access to electronic cells.

Honeywell's Electronic Air Cleaners are among the industry's most efficient for removing airborne dust, lint, pollen, soot, tobacco and cooking smoke from the atmosphere of a centrally heated or cooled structure. Available in a full range of sizes and configurations. Honeywell air cleaners combine top quality construction with ease of installation and maintenance. All models are UL listed.

picture of Space-Gard air cleaner - file size-3.8k Space-Gard Non-Electronic Air Cleaner- The Space-Gard air cleaner uses an exclusive media filtering process to remove airborne pollutants, and contains no electrical components or moving parts. The unit requires no service, generates no toxic ozone, and is not affected by variations in relative humidity or temperature. The only maintenance required is periodic replacement of the filter media approximately once a year under normal conditions.

The high-efficiency Space-Gard provides 78.6 square feet of filtering surface and can effectively remove up to 99% of all pollen and spores, and up to 90% of smaller particle pollutants such as dust, lint, smoke and soot. An important advantage of media type filtering is that the unit's efficiency actually increases as the media becomes loaded, providing highly effective filtration of particles as small as 1 micron. Great for tough-to-get-to units (e.g. attics and crawl spaces)

This unit is easily adaptable to virtually any type of forced air duct system and air flow configuration. No electrical installation is required.

Pliotron Electrostatic Air Filters- Pliotron's polyethylene media carries a strong electrostatic charge, both positive and negative, that attracts air-borne particles and holds them by strong electrostatic attraction. The result is effective, efficient, economical filtration even removing sub-visible particles 10 microns and smaller.

Stops fine dirt, dust, lint and microscopic particles.

The filter is self-charging as a result of air flow through the media (no expensive, troublesome power supplies required). The Pliotron filter is a permanent type (it should never have to be replaced). It is easily cleaned with a garden hose and is very safe (non-electric). An Industry favorite.

Air Booster Fans- Do you have one or two vents that you just don't get enough air out of? A booster fan will help!
For round metal or flexible duct. Easily installed in ducts to boost air flow to any hard to heat or hard to cool room. May be wired in parallel with blower for simultaneous operation or with optional adjustable fan switch. Units are 115 volts and available in 5", 6", 7", 8" and 10" diameters.

Condensate pumps- Condensate Pump, file size 3k

If you have ever had your condensate drain get blocked with dirt and leak water through your ceiling or in your finished basement, then a condensate pump might be for you.

With a condensate pump, the water is safely pumped outside the house or into any available drain, sink, or sump. Inexpensive condensate units are designed for simple installation and trouble-free service. Completely self contained with stainless steel pump shaft, snap-action float switch, check valve with 3/8"hose connection and a 6 ft. power cord.

[Available in 120 volt and 240 volt models.]